Status display / Error codes
The symbols in the table below show the meter’s operational status. The status messages only appear in
the main display (energy)! The temporary display of the warning triangle can be caused by special operat-
ing states and does not always mean that the device is malfunctioning. However, should the symbol be
displayed over a longer period of time, you should contact the service company.
Error codes show faults detected by zelsius
®
C5-IUF. If more than one error appears, the sum of the error codes is
displayed: Error 1005 = error 1000 and error 5.
Symbol
Status Event
External voltage -
Flow existent -
Attention! Check system/device for error
Symbol ashing: Data transmission
Symbol constantly displayed: optical interface active
-
-
Emergency operation. Exchange device
Code
Error Event
1 Temperature out of measuring range Check temperature
2 Temperature out of measuring range Check temperature
3 Short-circuit return sensor Check temperature
4 Interruption return sensor Check temperature
5 Short-circuit supply sensor Check temperature
6 Interruption supply sensor Check temperature
7 Battery voltage Exchange device
8 Hardware error Exchange device
9 Hardware error Exchange device
10 Error in the measuring system Exchange device
20 No water in the measuring tube Check operating pressure
30 Reverse water flow detected Check installation position
40 Air inside the medium Vent system
50 Measured value outside overload range Check dimensioning
100 Hardware error Exchange device
800 Wireless interface Exchange device
1000 Status end of the battery Exchange device resp. battery
2000 Status initial verification expired Exchange device